An administrator has been tasked to reboot a node in an encrypted vSAN cluster. The vSAN disk groups on that node become locked after rebooting the node.
Which step should be performed to exit the locked state?
A. Manually replace the Host Encryption Key (HEK) of each affected host.
B. Restore the communication with the KMS server, and re-establish the trust relationship.
C. Replace the caching device in each affected disk group.
D. Run /etc/init.d/vsanvpd restart to rescan the VASA providers.
A company hosts a vSAN 7 stretched cluster for all development workloads. The original sizing of a maximum of 250 concurrent workloads in the vSAN cluster is no longer sufficient and needs to increase to at least 500 concurrent workloads within the next six months.
To meet this demand, the original 8-node (4-4-1) cluster has recently been expanded to 16 nodes (8-8-1).
Which three additional steps should the administrator take to support the current growth plans while minimizing the amount of resources required at the witness site? (Choose three.)
A. Add the new vSAN witness appliance to vCenter Server.
B. Deploy a new large vSAN witness appliance at the witness site.
C. Configure the vSAN stretched cluster to use the new vSAN witness.
D. Deploy a new extra large vSAN witness appliance at the witness site.
E. Upgrade the vSAN stretched cluster to vSAN 7.0 U1.
F. Configure the new vSAN witness as a shared witness appliance.
Upon investigating a workload performance issue, a vSAN administrator observed a high backend IOPs on a vSAN cluster.
Which two causes explain this behavior? (Choose two.)
A. The cluster DRS threshold has been set to Aggressive.
B. There is a vSAN node failure.
C. The vSAN Resync throttling is enabled.
D. The object repair timer value has been increased.
E. The vSAN policy protection level has changed from FTT=0 to FTT=1.
An administrator wants to check the performance metrics for the workloads and their virtual disks that are running on a vSAN cluster, but no statistical charts are displayed in the vSphere client.
Why is this behavior being seen?
A. vSAN network diagnostic mode is not enabled.
B. vSAN proactive tests haven't been run yet.
C. vSAN performance service is turned off.
D. vSAN performance verbose mode is not enabled.
An administrator has been tasked with enabling encryption for existing virtual machines on a vSAN cluster. Which three prerequisites must be satisfied before completing the task? (Choose three.)
A. Create an encryption storage policy
B. Enable Data-In-Transit encryption first
C. Enable that the virtual machines are powered on
D. Verify if a role with privilege “Cryptographic operations.Encrypt new” is assigned
E. Verify if a role with privilege “Cryptographic operations.Migrate” is assigned
F. Establish a trusted connection with the KMS
An administrator has received an alert indicating that a single capacity device is close to failing within the production vSAN Cluster. The administrator must now complete preemptive maintenance on the vSAN Cluster without impacting the availability of workloads or vSAN File Services.
The following information is known about the vSAN Cluster: vSAN 7.x Cluster vSAN node count: 8 De-Duplication and Compression: Enabled. Encryption: Disabled Current Utilization: 45% Disk Groups: 2 Devices per node: 2 x 400 GB SSD, 6 x 1.8 TB SSD
Which three steps should the administrator take to successfully complete the task? (Choose three.)
A. Remove the affected Disk Group from the vSAN Cluster, and choose Full Data Migration.
B. Replace the failed disk with a storage device that is identical in class and capacity.
C. Remove the affected Disk Group from the vSAN Cluster, and choose No Data Migration.
D. Replace the failed disk with a storage device that is identical in class but smaller in capacity.
E. Put the affected vSAN host into maintenance mode to physically replace the storage device.
F. Remove the affected Disk from the Disk Group, and choose Full Data Migration.
Due to the success of the recently deployed developer-only private cloud solution, a company has a new requirement to at least double the usable capacity in their all-flash vSAN cluster.
The vSAN cluster is deployed into a co-located datacenter that is owned by a third-party hosting company. The hosting company charges a fixed monthly cost for rack space and power consumption. The service owner has been given a limited budget for additional hardware purchases, but not for on-going co-location costs.
The current vSAN cluster has the following configuration: 10 vSAN Nodes with 2 CPUs (20 cores), 512 GB RAM
1 Disk Group per vSAN node
-1 x 400 GB
-4 x 1.8 TB
De-duplication and Compression is enabled.
vSAN Capacity is currently:
-Total: 72 TB
-Usable: ~40 TB (FTT1/RAID1) and ~60 TB (FTT1/RAID5).
As a result of any action taken, the service owner would like to ensure that overall availability of the vSAN cluster is increased.
Which two recommendations meet the requirement to increase capacity while maintaining service availability? (Choose two.)
A. Install an additional 400 GB SSD and 4 x 1.8 TB SSDs per vSAN node.
B. Update the existing Disk Group, and claim the newly installed drives for each node.
C. Create a new Disk Group, and claim the newly installed cache and capacity SSD drives for each node.
D. Install an additional 3 x 1.8 TB SSDs per vSAN node.
E. Replace existing SSDs with an 800 GB SSD and 4 x 3.8 TB SSDs per vSAN node.
After a vSAN Witness Appliance network configuration, the vSAN administrator notices that vSAN traffic flows from vmk0 (Management Traffic) rather than vmk1 (vSAN Traffic).
Which step should be taken to resolve this issue?
A. Configure vmk0 with IP address on the same range as that of vmk1.
B. Tag the vmk0 for vSAN traffic.
C. Configure vmk1 with IP address on the different network than that of vmk0.
D. Tag the vmk1 for Witness traffic.
An organization has two vSAN clusters managed by the same vCenter Server, each providing 100TB of storage. The first cluster runs at 75% of its storage capacity, and the second cluster runs at 50% of its storage capacity.
The company also has the following:
An iSCSI array of 300TB. which runs at 76% of its capacity A NAS system of 200TB, which runs at 10% of its capacity A Fiber channel (FC) array of 300TB, which runs at 80% of its capacity
The administrator is asked to add an additional 25TB of storage to the first cluster. The administrator is also made aware that there is no budget to purchase new hardware and that the vSAN Storage Policy Based Management must be kept in place.
Which storage option will work for this use case?
A. Create an HCI Mesh using the first cluster's datastore.
B. Obtain additional free capacity from the existing NAS storage.
C. Obtain additional free capacity from the existing FC storage.
D. Create an HCI Mesh using the second cluster's datastore.
An architect is tasked to design a VMware Horizon Solution with vSAN. The architect needs to use a solution to host the user's profile shares in a highly available manner, and it must be guest OS independent.
Which solution will match these requirements?
A. Cluster out of the box
B. Cluster in a box
C. NFS on vSAN
D. iSCSI on vSAN
During a design workshop for a stretched vSAN cluster, the requirement that some of the VMs be configured with no-mirror between sites was discussed.
Which three recommendations should the architect provide to address an event of a network partition between two sites? (Choose three.)
A. Host isolation response must exclude the VMs required
B. The default gateway must be used as the only isolation address
C. One of isolation addresses should reside in the site 1 data center
D. VMware vSphere DRS rules to force the VMs to run where the data resides
E. One isolation address reachable only from the witness appliance in both sites
F. One of isolation addresses should reside in the site 2 data center
During a planning session for new vSAN clusters in multiple data centers, the customer relayed the following information:
Highest possible mitigation during a host failure in terms of capacity. A constraint in this year's IT budget.
What should the architect recommend?
A. Enable operations reserve. A minimum cluster of 3 vSAN nodes.
B. Enable host build reserve. A minimum cluster of 4 vSAN nodes.
C. Enable performance services. A minimum cluster of 6 vSAN nodes.
D. Enable IOInsight Metrics. A minimum cluster of 2 vSAN ROBO nodes.
A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1. The company
wants to ensure that the same vSAN process can be used in the future.
During the discovery phase, the consultant found the following information about the existing environment:
The vCenter Server is currently version 7.0.
The vSAN Cluster has the following configuration:
-vSAN version: 7.0
-Number of vSAN nodes: 6
-Encryption: enabled
-Deduplication and Compression: enabled
-Fault Domains: 1
-vSAN Capacity Utilization: 60% Each vSAN node has the following configuration:
-ESXi version: VMware vSphere 7.0
-CPU: 2 processors, 20 cores
-RAM: 1024GB RAM.
-Disk: 2 Cache SSDs and 6 Capacity SSDs
-Network: 4 x 10GbE All current hardware (which is from a single vendor) is listed on the vSAN Compatibility Guide for vSAN 7.
Which three recommendations should the consultant make to ensure that the vSAN cluster upgrade is completed? (Choose three.)
A. Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the baselines capability within VMware Update Manager (VUM).
B. Disable vSAN Encryption before starting the upgrade process.
C. Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the images capability within VMware Update Manager (VUM).
D. Set VMware Distributed Resource Scheduling (DRS) to partially automated.
E. Upgrade to VMware vCenter Server 7.0 U1.
F. Choose the Allow reduced redundancy option.
An architect is designing a vSAN cluster.
Which storage controller option will yield optimal performance?
A. Hugh queue depth
B. Set caching to 50% read on the controller
C. Enable battery write-back caching
D. RAID 0
An administrator is planning to deploy cloud-native workloads onto the vSAN Direct datastore. Which storage policy structure rule is supported?
A. Host-based rules
B. vVOL storage rules
C. Tag-based placement rules
D. Storage performance-based rules